Photo |
Description |
Item No. |
 |
Duromac CP 250
|
Solid sacrificial zinc anode for retrofit installation.
|
Connection wire: insulated copper wire. 250g of zinc per anode. Theoretical charge: 190Ah per anode.
|
Package with 24 anodes incl. Duroperm CP 600ml. |
|
D.003.0022 |
 |
Duromac CP 250T
|
Solid sacrificial zinc anode for retrofit installation.
|
Connection wire: insulated copper wire. 250g of zinc per anode. Theoretical charge: 190Ah per anode.
|
Package with 24 anodes incl. Duroperm CP 600ml. |
|
D.003.0032 |
 |
Titanium Wire 2.5sqmm
|
Insulated titanium wire, 2.5 square mm cross sectional area. Main wire for anode connection for anodes with titaium wires.
|
|
100m |
|
D.003.0036 |
 |
Titanium Crimp
|
Titanium crimp connectors for connecting titanium anode wires to main wire.
|
|
1000 pcs. |
|
D.003.0037 |
 |
Fixing Wedges
|
Zinc wedges to keep anodes in places during overhead installation.
|
|
1000 pcs. |
|
D.003.1012 |
 |
ZLA
|
ZLA is a zinc sacrificial sheet anode which is applied directly to the concrete surface for corrosion control of steel in concrete. The application is realised by an ion-conductive adhesive which is pre-applied. ZLA is supplied with the applied adhesive and is ready to use. The protective PET-liner is removed prior to application of the zinc sheet. The current required for cathodic protection is provided by the galvanic link of the steel reinforcement and the zinc sheet. No external power is required.
|
|
|
|
D.003.0201 |
 |
ZDA
|
Sacrificial zinc anodes embedded in an ion-conductive auto moistening paste, for cathodic protection of reinforced concrete structures with a cotton sleeve protection against concrete casting. For protection of reinforced concrete structures which are newly build or precasted.
|
|
|
|
D.003.0202 |
 |
MAS
|
MAS (Magnesite Anode System) is a protection system specifically devoloped to control the corrosion of the reinforcement caused by magnesite floorings.
|
|
|
|
D.003.0203 |
 |
Siliguard
|
Siliguard Coat is a one component inorganic low alkaline acqueous composite paint for active corrosion control of steel in concrete. Once applied, the paint -consisting of concrete's own ingredients with an open porous structure- guarantees excellent adhesion and acid proof properties.
Siliguard Coat can be applied either by brushing, rolling or spraying.
|
|
|
|
D.003.0204 |
 |
MMO-Anode
|
Discrete MMO-anode for impressed current systems.
|
The anode is manufactured as a discrete MMO-titanium anode. The heart of the anode is based on a MMO-coated titanium electrode. The anodes is specifically designed for application in pre-drilled holes which can be used in combination with our silicate based grout or just traditional mineral based grouts preferably recommended by certified CP designers or engineers.
|
|
|
D.003.0301 |